letzte Aktualisierung
05.06.2025
Konfigurations-Code KLF40CNHS_16RCG0


Bestellnummer 106H3413
Typenbezeichnung KLF4.0CNHS
Produkt Status Produktion - Variante
Datenblatt Download
Konfiguration
Polynom KLF40CNHS_16G0 KLF40CNHS_16RCG0
Spannungsbereich 95 … 140 95 … 140
Frequenz 60 60
hohes Startmoment ja nein
Betriebskondensator nein ja
Motordrehzahl (UpM) 3500 3500
drehzahlgeregelt nein nein
Kältemittel R290 R290
Besonderheiten tropische Anwendung empfohlen nein nein
Schwerlast Pull Down möglich ja ja
mobiler Betrieb möglich nein nein
Heiß-Gas Abtauung möglich ja ja
Kühlung erforderliche Kühlung d. Verdichters Max. ambient temp.: 43°C F2 (fan 3m/s) Max. ambient temp.: 43°C F2 (fan 3m/s)
Anwendungsdiagramm = kurz = fortlaufend
CECOMAF CECOMAF ULT LBP MBP HBP ULT LBP MBP HBP
Kälteleistung [W | Btu/h] n/a | n/a 163 | 557 320 | 1093 n/a | n/a n/a | n/a 165 | 563 324 | 1106 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.11 | 3.8 1.68 | 5.7 n/a | n/a n/a | n/a 1.17 | 4 1.78 | 6.1 n/a | n/a
ASHRAE ASHRAE ULT LBP MBP HBP ULT LBP MBP HBP
Kälteleistung [W | Btu/h] n/a | n/a 220 | 751 404 | 1380 n/a | n/a n/a | n/a 222 | 758 409 | 1397 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.45 | 5 2.04 | 7 n/a | n/a n/a | n/a 1.53 | 5.2 2.17 | 7.4 n/a | n/a
EN12900 EN12900 ULT LBP MBP HBP ULT LBP MBP HBP
Kälteleistung [W | Btu/h] n/a | n/a 123 | 420 363 | 1240 n/a | n/a n/a | n/a 124 | 423 367 | 1253 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.02 | 3.5 2.09 | 7.1 n/a | n/a n/a | n/a 1.07 | 3.7 2.2 | 7.5 n/a | n/a
ARI540 ARI540 ULT LBP MBP HBP ULT LBP MBP HBP
Kälteleistung [W | Btu/h] n/a | n/a 181 | 618 381 | 1301 n/a | n/a n/a | n/a 183 | 625 386 | 1318 n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.23 | 4.2 2.04 | 7 n/a | n/a n/a | n/a 1.29 | 4.4 2.16 | 7.4 n/a | n/a
AHAM AHAM ULT LBP MBP HBP ULT LBP MBP HBP
Kälteleistung [W | Btu/h] n/a | n/a 247 | 844 n/a | n/a n/a | n/a n/a | n/a 249 | 850 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.75 | 6 n/a | n/a n/a | n/a n/a | n/a 1.84 | 6.3 n/a | n/a n/a | n/a
VSD_opt1 VSD_opt1 ULT LBP MBP HBP ULT LBP MBP HBP
Kälteleistung [W | Btu/h] n/a | n/a 226 | 772 n/a | n/a n/a | n/a n/a | n/a 228 | 779 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.71 | 5.8 n/a | n/a n/a | n/a n/a | n/a 1.8 | 6.1 n/a | n/a n/a | n/a
VSD_opt2 VSD_opt2 ULT LBP MBP HBP ULT LBP MBP HBP
Kälteleistung [W | Btu/h] n/a | n/a 209 | 714 n/a | n/a n/a | n/a n/a | n/a 211 | 721 n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a 1.51 | 5.2 n/a | n/a n/a | n/a n/a | n/a 1.58 | 5.4 n/a | n/a n/a | n/a
lowTemp lowTemp ULT LBP MBP HBP ULT LBP MBP HBP
Kälteleistung [W | Btu/h] n/a | n/a n/a | n/a n/a | n/a n/a | n/a n/a | n/a n/a | n/a n/a | n/a n/a | n/a
COP | EER [W/W | Btu/Wh] n/a | n/a n/a | n/a n/a | n/a n/a | n/a n/a | n/a n/a | n/a n/a | n/a n/a | n/a