HZK95AA Compresseur Fiche technique
220-240V/50Hz Stationary Cooling Solutions

Déplacement de - à 5.6 - 12.5 cm³ et couvrent une plage de puissance frigorifique (ASHRAE) de:

  • LBP: 92–260 W
  • MBP: 0–0 W
  • RAP: 0–0 W
K-Series Compressors
Variantes pour HZK95AA une variante 1
Numéro de code CDO00078
Désignation de type HZK95AA
État du produit Production - active
Performance Check Performance
Data Sheet Télécharger
Modèle 3D
Source de courant 220-240V/50Hz Yes
110-115V/50Hz No
115-127V/60Hz No
208-230V/60Hz No
12-24V DC No
48V DC No
Réfrigérants R170 No
R1270 No
R134a No
R513A No
R1234yf No
R290 No
R404A No
R452A No
R407C No
R600a Yes
Applications LBP Yes
MBP No
ULT No
Moteurs RSIR No
RSCR Yes
CSIR No
CSCR No
DC/PM No
Équipement initial préassemblé No
Dimensions la taille [mm | in.] 176.5 | 6.95
Poids [kg | lbs.] 9.6 | 21.2
Connecteur de décharge ⌀ [mm | in.] 5.15 | 0.2
Matériel de décharge Copper
Connecteur de processus ⌀ [mm | in.] -6 | -0.24
Matériau de processus Copper
Connecteur d'aspiration ⌀ [mm | in.] 6.15 | 0.24
Matériel d'aspiration Copper
Conception Evap. plateau Oui
Déplacement [cm³ | cu.in.] 9.6 | 0.59
Charge d'huile [cm³ | fl.oz.] 140 | 4.73
Type d'huile Mineral
Performance Vitesse du moteur [tr/m] 2900
ULT Cooling capacity [W | Btu/h] 0 | 0
ULT COP [W/W | Btu/Wh] 0 | 0
Capacité de refroidissement LBP [W | Bth / h] 171 | 585
COP de HBP [W / W | Btu / Wh] 1.99 | 6.8
MBP Capacité de refroidissement [W | Bth / h] 0 | 0
MBP COP [W / W | Btu / Wh] 0 | 0
Capacité de refroidissement HBP [W | Bth / h] 0 | 0
COP de HBP [W / W | Btu / Wh] 0 | 0
Approbations EN 60335-2-34 with Annex AA yes
  • Models for Tropical Conditions
    The ability to start under low voltage conditions without reverse rotation and without stalling presents an outstanding solution for harsh environments

  • Easily Accessible Start Equipment
    Simple installation of electrical components, which reduces installation times and simplifies maintenance work

  • Low Noise and Low Vibrations
    Features that are highly appreciated in residential and small commercial applications

  • Superior Efficiency
    COP level up to 1.99 under ASHRAE LBP conditions (HZK models)

We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. We also share information about your use of our site with our social media, advertising and analytics partners. Click "Manage preferences" if you would like to read more about our cookies and adjust your preferences. By clicking "Accept all", you agree to the use of all cookies as described in our Privacy Policy.