Variants for HXK12AT variant 1 variant 2 variant 3 variant 4
Code number 16409500 CDO00177 CDO00219 16470500
Type designation HXK12AT HXK12AT HXK12AT HXK12AT
Product status Production - Active Production - Active Production - Active Production - Variant
Performance Check Performance Check Performance Check Performance Check Performance
Data Sheet Download Download Download
3D Model
Power supply 220-240V/50Hz Yes Yes Yes Yes
110-115V/50Hz No No No No
115-127V/60Hz No No No No
208-230V/60Hz Yes Yes Yes Yes
12-24V DC No No No No
48V DC No No No No
Refrigerants R170 No No No No
R1270 No No No No
R134a No No No No
R513A No No No No
R1234yf No No No No
R290 No No No No
R404A No No No No
R452A No No No No
R407C No No No No
R600a Yes Yes Yes Yes
Applications LBP Yes Yes Yes Yes
MBP No No No No
HBP No No No No
ULT No No No No
Motors RSIR Yes Yes Yes Yes
RSCR Yes Yes Yes Yes
CSIR No No No No
CSCR No No No No
DC/PM No No No No
Pre-assembled start equipment No No No No
Dimensions Height [mm | in.] 173.5 | 6.83 173.5 | 6.83 173.5 | 6.83 173.5 | 6.83
Weight [kg | lbs.] 8.9 | 19.6 8.9 | 19.6 8.9 | 19.6 8.9 | 19.6
Discharge connector ⌀ [mm | in.] 5.15 | 0.2 5.15 | 0.2 5.15 | 0.2 5.15 | 0.2
Discharge Material Copper Cu-plated steel Cu-plated steel Copper
Process connector ⌀ [mm | in.] -6 | -0.24 -6 | -0.24 -6 | -0.24 -6 | -0.24
Process Material Copper Copper Copper Copper
Suction connector ⌀ [mm | in.] 6.15 | 0.24 6.15 | 0.24 6.15 | 0.24 6.15 | 0.24
Suction Material Copper Cu-plated steel Cu-plated steel Copper
Design Evap. tray fixture yes yes
Displacement [cm³ | cu.in.] 11.1 | 0.68 11.12 | 0.68 11.12 | 0.68 11.1 | 0.68
Oil Charge [cm³ | fl.oz.] 165 | 5.58 165 | 5.58 165 | 5.58 165 | 5.58
Oil Type Mineral Mineral Mineral Mineral
Performance Motor Speed [rpm] 2900 2900 2900 2900
ULT Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0 0 | 0
ULT COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0 0 | 0
LBP Cooling capacity [W | Btu/h] 198 | 678 198 | 678 198 | 678 198 | 678
LBP COP [W/W | Btu/Wh] 1.67 | 5.7 1.67 | 5.7 1.67 | 5.7 1.67 | 5.7
MBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0 0 | 0
MBP COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0 0 | 0
HBP Cooling capacity [W | Btu/h] 0 | 0 0 | 0 0 | 0 0 | 0
HBP COP [W/W | Btu/Wh] 0 | 0 0 | 0 0 | 0 0 | 0
  • Models for Tropical Conditions
    The ability to start under low voltage conditions without reverse rotation and without stalling presents an outstanding solution for harsh environments

  • Easily Accessible Start Equipment
    Simple installation of electrical components, which reduces installation times and simplifies maintenance work

  • Low Noise and Low Vibrations
    Features that are highly appreciated in residential and small commercial applications

  • Superior Efficiency
    COP level up to 1.99 under ASHRAE LBP conditions (HZK models)

Secop K hermetic refrigeration compressor (GTK, HKK, HMK, HTK, HXK, HZK)

We use cookies to personalize content and ads, to provide social media features and to analyze our traffic. We also share information about your use of our site with our social media, advertising and analytics partners. Click "Manage preferences" if you would like to read more about our cookies and adjust your preferences. By clicking "Accept all", you agree to the use of all cookies as described in our Privacy Policy. Privacy Policy